New MD100 Photometer

Datasheet:  


Product Description
Precise Water Analysis in High-Quality Design: Small I Mobile I Rapid

The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparency sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling. The calibration and software-based adjustment options mean that the MD 100 is also suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life, VARIO powder reagents or using liquid reagents.

Scroll Memory (SM)
To avoid unnecessary scrolling for the required test method, the instrument memorizes the last method used before switching off the instrument. When the instrument is switched on again, the scroll list comes up with the last used test method fi rst.

Zero Setting (OTZ)
For certain versions of the instrument it is not necessary to zero the instrument each time. The zero setting is held in memory (One Time Zero - OTZ). The zero setting can be confi rmed whenever it is usefull.

Technical Data

Optics LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3different interfernce filters are used.
Wavelength Accuracy ± 1 nm
Photometric
Accuracy4)
3% FS (T = 20°C - 25°C)
Photometric Resolution 0.01 A
Power Supply 4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
Auto - OFF automatic switch-off
Display backlit LCD (on keypress)
Storage internal ring memory for 16 data sets
Interfaces Infrared interface for test data transfer
Additional feature real time clock and date
Calibration factory calibration and user calibration. Reset to factory calibration possible
Dimensions 155 x 75 x 35 mm (L x W x H)
Weight basic unit approx. 260 g
CE-Conformity

4)tested with standard solutions

 


DescriptionPart NoPrice 
Chlorine, tablet reagents (OTZ) 0.01-6.0mg/ lCl2, alternatively with liquid reaents 0.02-4mg/lCl2ET276000€485.71  
Chlorine powder reagents 0.02-2.0mg//l Cl2 , 0.1-8.0mg/l Cl2ET276010€485.71  
Chlorine DUO, for 2 types of reagents 1. Tabler Reagents 2. Powder ReagentsET276020€485.71  
Chlorine dioxide, tablet reagents 0.05 - 11 mg/ClO2ET276030€0.00  
Chloride dioxide, powder reagents 0.05- 3.8 mg/l ClO2ET276035€0.00  
Phosphate tablet reagents 0.05-4.0 mg/l PO4ET276040€0.00  
Phosphate, powder reagents 0.06-2.5 mg/l PO4ET276045€0.00  
Iron . tablet reagents 0.02 -1.0 mg/l FeET276050€0.00  
Iron TPTZ powder reagents 0.02-1.8mg/l FeET276055€0.00  
Iron powder reagents 0.02-3.0 mg/lFeET276056€0.00  
Ammonia, tablet reagents 0.02-1.0mg / I NET276060€0.00  
Ammonium, powder reagents 0.01 - 0.8 mg/I NET276065€0.00  
Ammonia, free powder reagents 0.01.0.5mg/I N, Monochloramine 0.04-4.5mg/lCL2ET276070€0.00  
Copper, tablet reagents 0.05-5.0 mg/l CuET276080€0.00  
Copper, powder reagents 0.05-5.0 mg/l CuET276085€0.00  
Fluoride, without reagents 0.5-2.0mg/lFET276090€0.00  
Manganese LR, tablet reagents 0.2-4.0 mg/l MnET276100€0.00  
Manganese LR, powder reagents 0.01-0.7 mg/l MnET276105€0.00  
Manganese HR, powder reagents 0.1-18 mg/l MnET276106€0.00  
Silica, tablet reagents 0.05-4.0 mg/l SiO 2ET276110€0.00  
Silica LR, powder reagents 0.1-1.6mg/l SiO2ET276115€0.00  
Silica HR, powder reagents 1-90 mg/l SiO 2ET276116€0.00  
COD , tube testET276120€521.40  